Three precautions that are easy to ignore when using dc sockets

When we use dc sockets, we need to pay attention to more places. For example, we often overlook the lack of protective technical measures for DC sockets, the optional installation of DC socket wires, and the low position of DC sockets. In this article, the editor of okplazas.com will give you a specific introduction to these aspects, and I hope it will be helpful to you.

Note 1: The DC socket lacks protective technical measures

And soot water power kitchen and bathroom, so that water splash is preferably installed in the outlet box or plastic baffle panel, which can effectively prevent short circuit due to the intrusion of oil and moisture. Families with children, in order to prevent children from touching the poke socket with their fingers or metal objects, will have to use secure sockets and insurance brackets. In addition, when installing some decoration companies with three-hole sockets, the ground is often non-existent, and even the ground wire is directly connected to the gas pipeline. Professionals pointed out that these practices are dangerous. Grounding and electrical enclosures will cause electric shocks if they leak electricity.

Note 2: DC socket wires can be installed at will

The power cord must use copper wire cross-section. If you live in an old house, be sure to replace the original aluminum wire with copper wire. Since the aluminum wire is easily oxidized, the joint is easy to catch fire. The survey shows that in households that use aluminum wires, the incidence of electrical fires is dozens of times that of copper wires. In addition, in order to be beautiful, many families will use slotted and buried wires and concealed pipe laying methods. Xia Dong reminded that the principle of "live wire into the switch and neutral wire into the lamp holder" must be followed when wiring, and leakage protection should be set on the socket. Device.

Note 3: The position of the DC socket is too low

When installing DC power sockets, many student families feel that they are not too high and will not hinder the aesthetics. They will install them in a lower concealed engineering position. However, "497" of the Institute of Electrical Engineering and Technology of the Chinese Academy of Social Sciences said that this can easily cause water to splash into the socket when mopping the ground, which will affect and cause leakage safety accidents. According to the relevant regulations in the industry, the best service time between the exposed socket and the ground should not be less than 1.8 meters; the concealed socket must not be less than 0.3 meters from the ground. The sockets of the kitchen and bathroom should be at least 1.5 meters above the ground, and the sockets of the air conditioner must be at least 2 meters above the ground.

The above are several aspects that we tend to overlook when using DC sockets. okplazas.com is a professional DC socket supplier with a complete and scientific quality management system, and its strength and product quality have been recognized by the industry.