Siemens dual power switch application conditions

The ESD standards in pieces

ESD guidelines must be followed when handling dual power switch 3KC4 and 3KC8 series devices.

◆ Electrostatic Sensitive Device (ESD)

ESD sensing elements can be destroyed by voltages and energies far below the human perception threshold, which occurs at the moment when a person touches the device or equipment without ESD treatment. ESD components that suffer from this voltage are usually not immediately identified as defective because such failures do not occur until after the equipment has been operating for a long time.

Note:

1. Electrostatic sensitive equipment

Electronic modules contain components that can be damaged by electrostatic discharge. These modules can easily be corrupted by incorrect operations.

● The body must release its own static electricity before contact with electronic devices. This is done by direct contact with an earthed conductor, such as an exposed metal part of a switchgear or water pipe.

● Always hold onto the plastic casing of the device.

● Electronic modules should not be in contact with electrical insulation materials, such as plastic film, plastic parts, insulating desks or cloth made of man-made fibers.

● Always place the electrostatic sensitive device on the conductive body.

● Always store and transport electronic modules or devices in ESD secure conductive packaging, such as metallized plastic or metal containers, and always place devices in their packaging prior to installation.

2. Storage and transportation

If you must store or transport the device in non-conductive packaging, you must first wrap the device in ESD safe conductive material, such as conductive foam rubber, ESD package.

◆ The diagram of the ESD work center is shown below

Transmitter|Encoder|Soft starter|Power supply|VFD|Light curtain|Servo products|Human-machine interface|Solenoid valve|Cylinder|Actuator|Flow meter|Transformer|Thyristor|Sensor|Deceleration drive gearbox reducer|Linear guide|Circuit breaker|Refrigeration compressorAll industrial products of okplazas are purchased from the original factory or formal channels of agents to ensure the original authenticity, which perfectly solves the problem of industrial product sample procurement and small-batch procurement for the majority of engineers and purchasing personnel.

ESD posture; (2) ESD posture; ESD sitting position and standing position.

Protective measures: A. Conductive floor; B. ESD desk; C. ESD shoes; D. ESD uniform; E, ESD bracelet; F. Grounding connection of the cabinet.

◆ Common terms and letter meanings of Siemens dual power switch

1, 1PH+N single phase power network containing single and neutral lines;

2. 3PH three-phase three-wire grid containing three-phase no neutral lines;

3, 3 pH +N three-phase four-wire power grid including three-phase and neutral lines;

4. AC AC voltage;

5. ATS dual power switch (electronic module);

6. ATSE dual-power switching switch electrical appliances;

7. Cu;

8. DC DC voltage;

9. DPS dual power converter;

10. EN European standard;

11. ESD electrostatic discharge;

12. IEC International Electrotechnical Committee;

13. IP protection level;

14. N neutral line;

15. RJ standard socket;

16. PH phase;

17. RTSE remote control transfer switch electrical appliance;

18, Δ U voltage threshold;

19, Δ F frequency threshold;

20. I2t permissible energy;

21. Icm short circuit connection ability;

22. Icw short-time withstand current;

23. Rated Ue working voltage;

24. VImp shock withstand voltage;

Un rated voltage.

◆ Siemens dual power switch environmental conditions

● IP20 protection grade can prevent direct contact with the motor operating mechanism;

● After the terminal cover plate is installed correctly according to the rules, it has the IP20 protection class, which can prevent the direct contact interface;

● IP00 protection class is available without terminal cover;

◆ Working conditions of Siemens dual power switching switch

● The temperature range is from -20℃ to +40℃ with no reduction;

● The temperature range is -20 ° C to +70 ° C, and the correction factor Kt of downsizing must be taken into account.

Transmitter|Encoder|Soft starter|Power supply|VFD|Light curtain|Servo products|Human-machine interface|Solenoid valve|Cylinder|Actuator|Flow meter|Transformer|Thyristor|Sensor|Deceleration drive gearbox reducer|Linear guide|Circuit breaker|Refrigeration compressorAll industrial products of okplazas are purchased from the original factory or formal channels of agents to ensure the original authenticity, which perfectly solves the problem of industrial product sample procurement and small-batch procurement for the majority of engineers and purchasing personnel.

The following simplified method is used here to calculate the reduction:

Thu ≤Ith*Kf, in rare cases, precise deweighting is specifically required.

● Air humidity is 80%, temperature is 55℃, no condensation;

● Air humidity at 95%, temperature at 40℃, no condensation.

● The double power switch can reach the highest altitude of 2000 meters without lowering the forehead;

● To reach higher altitudes, the correction factor for the reduction in the figure below must be taken into account.

Transmitter|Encoder|Soft starter|Power supply|VFD|Light curtain|Servo products|Human-machine interface|Solenoid valve|Cylinder|Actuator|Flow meter|Transformer|Thyristor|Sensor|Deceleration drive gearbox reducer|Linear guide|Circuit breaker|Refrigeration compressorAll industrial products of okplazas are purchased from the original factory or formal channels of agents to ensure the original authenticity, which perfectly solves the problem of industrial product sample procurement and small-batch procurement for the majority of engineers and purchasing personnel.

◆ Siemens dual power switch storage conditions

● Dual power switch must be stored at -40℃ to +70℃;

● Maximum storage time up to 12 months;



● It is recommended to store in a dry, non-corrosive, salt-free environment;

● For dual power switch with current rating ≤630A, maximum 3 packs are allowed to be stacked together for storage;

● For dual power switch with current rating ≥800A, only single pack storage is allowed. Multiple packs are not allowed to be stacked together.

Siemens dual power switching applications

In toggle switch applications, the dual power toggle switch is described here as an innovative solution to complex source requirements. To monitor and control the source, an appropriate and independent Siemens dual power toggle switch controller must be used with the 3KC4 model.

The meanings of the symbols shown in the circuit diagram are as follows:

Transmitter|Encoder|Soft starter|Power supply|VFD|Light curtain|Servo products|Human-machine interface|Solenoid valve|Cylinder|Actuator|Flow meter|Transformer|Thyristor|Sensor|Deceleration drive gearbox reducer|Linear guide|Circuit breaker|Refrigeration compressorAll industrial products of okplazas are purchased from the original factory or formal channels of agents to ensure the original authenticity, which perfectly solves the problem of industrial product sample procurement and small-batch procurement for the majority of engineers and purchasing personnel.

The following table shows the toggle switch behavior. The following code indicates the availability of the source (transformer or generator) :

●1= source available;

●0= source unavailable;

● X = undefined source availability is meaningless.

The switching state of the dual power switch is described as follows:

●P1=P1 switch closed;

●P2=P2 switch closed;

●P3=P3 switch is closed, etc.

● X = nonsense (a toggle switch can be in any of three switching states I, 0, or II).

The following application scheme is suitable for Siemens dual power switch 3KC8 (with electronic module) and 3KC4 (with appropriate and independent switch controller).

◆ Switching application scheme of two-channel power supply and single-bus power supply

Switch (T1 (kVA) = T2 (kVA))

Switching switches can be used to switch between two sources of equal power (T1(kVA)=T2(kVA)) when there is an output load. The Siemens dual power switching 3KC8 series provides an ideal solution for power grid, power grid applications and power grid and generator applications, as shown in the figure below.

Transmitter|Encoder|Soft starter|Power supply|VFD|Light curtain|Servo products|Human-machine interface|Solenoid valve|Cylinder|Actuator|Flow meter|Transformer|Thyristor|Sensor|Deceleration drive gearbox reducer|Linear guide|Circuit breaker|Refrigeration compressorAll industrial products of okplazas are purchased from the original factory or formal channels of agents to ensure the original authenticity, which perfectly solves the problem of industrial product sample procurement and small-batch procurement for the majority of engineers and purchasing personnel.

◆ Switching application scheme of two-channel power supply and single-bus segmented power supply

Switch (T1(kVA) > T2/G(kVA))

In this application, the power of source I is greater than that of source II (T1(kVA) > T2/G(kVA)). This application usually USES a generator and a transformer, but for this application the Siemens dual power switching switch 3KC8 can also be converted between two transformers. In this case, the load can be divided into important load and non-important load, as shown in the figure below.

Transmitter|Encoder|Soft starter|Power supply|VFD|Light curtain|Servo products|Human-machine interface|Solenoid valve|Cylinder|Actuator|Flow meter|Transformer|Thyristor|Sensor|Deceleration drive gearbox reducer|Linear guide|Circuit breaker|Refrigeration compressorAll industrial products of okplazas are purchased from the original factory or formal channels of agents to ensure the original authenticity, which perfectly solves the problem of industrial product sample procurement and small-batch procurement for the majority of engineers and purchasing personnel.

Switch (T1 (kVA) = T2 (kVA))

A dual power switch can also provide an innovative solution for connecting two transformers of the same type with equal power (T1(kVA)=T2(kVA)), as shown in the figure below.

Transmitter|Encoder|Soft starter|Power supply|VFD|Light curtain|Servo products|Human-machine interface|Solenoid valve|Cylinder|Actuator|Flow meter|Transformer|Thyristor|Sensor|Deceleration drive gearbox reducer|Linear guide|Circuit breaker|Refrigeration compressorAll industrial products of okplazas are purchased from the original factory or formal channels of agents to ensure the original authenticity, which perfectly solves the problem of industrial product sample procurement and small-batch procurement for the majority of engineers and purchasing personnel.

◆ Switching application scheme of three-way power supply and single-bus power supply

Switch (T1 (kVA) = T2 (kVA) = G

A dual power switch can be used to switch between three sources (two transformers T1 and T2 and one generator G) when there is an output load. By using two switching switches, a complex application consisting of three equal power sources (T1(kVA)=T2(kVA)=G) can be implemented to enable the power supply to be maintained, as shown in the figure below.

Transmitter|Encoder|Soft starter|Power supply|VFD|Light curtain|Servo products|Human-machine interface|Solenoid valve|Cylinder|Actuator|Flow meter|Transformer|Thyristor|Sensor|Deceleration drive gearbox reducer|Linear guide|Circuit breaker|Refrigeration compressorAll industrial products of okplazas are purchased from the original factory or formal channels of agents to ensure the original authenticity, which perfectly solves the problem of industrial product sample procurement and small-batch procurement for the majority of engineers and purchasing personnel.

◆ Switching application scheme of three-way power supply and single-bus power supply

Switch (T1 (kVA) = T2 (kVA) = G

A dual power switch can be used to switch between three sources (two transformers T1 and T2 and one generator G) when there is an output load. By using two switching switches, a complex application consisting of three equal power sources (T1(kVA)=T2(kVA)=G) can be implemented to enable the power supply to be maintained, as shown in the figure below.

Transmitter|Encoder|Soft starter|Power supply|VFD|Light curtain|Servo products|Human-machine interface|Solenoid valve|Cylinder|Actuator|Flow meter|Transformer|Thyristor|Sensor|Deceleration drive gearbox reducer|Linear guide|Circuit breaker|Refrigeration compressorAll industrial products of okplazas are purchased from the original factory or formal channels of agents to ensure the original authenticity, which perfectly solves the problem of industrial product sample procurement and small-batch procurement for the majority of engineers and purchasing personnel.