  1. Schneider household miniature circuit breaker Resi9 series selection and principle

    Schneider household miniature circuit breaker Resi9 series selection and principle Schneider miniature circuit breaker Resi9 series features To ensure the safety of personnel and equipment in harsh environments, it can be said that the Resi9 series of Schneider miniature circuit breakers are a good choice for switching and protection in household electricity scenarios. It can ensure good safety in the maintenance process. The switch on the front of the circuit breaker has the VisiSafe "visible safety" sign. In any environment and condition, the role of VisiSafe is to ensure the safety and reliability of the lower-level circuit , The specific description is shown in the figure below.
    Read more »
  2. Schneider molded case circuit breaker NSC series selection parameters and accessories description

    Schneider molded case circuit breaker NSC series selection parameters and accessories description Schneider Molded Case Circuit Breaker NSC Series Overview This type of molded case circuit breaker is for industrial control and OEM manufacturing. Its rated operating current is 15A to 630A, and the number of poles it has is 3 poles and 4 poles.
    Read more »
  3. Siemens vacuum contactor 3RT123TF6 working principle manual

    Siemens vacuum contactor 3RT123TF6 working principle manual Overview of Siemens Vacuum Contactor 3RT12/3TF6 ◆Standard IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 (auxiliary switch)
    Read more »
  4. Siemens power contactor 3RT2 model parameter description

    Siemens power contactor 3RT2 model parameter description Overview of Siemens Power Contactor 3RT2 The connection system of the power contactor is connected to the main circuit busbar (with box terminal is optional), and the auxiliary and control circuit can choose screw terminal or spring terminal. Siemens contactor 3RT2 with screw terminal has models and specifications (size S00 to S3).
    Read more »
  5. Airtac standard cylinder SC series with valve sample

    Airtac standard cylinder SC series with valve sample Airtac standard cylinder SC series product overview
    Read more »
  6. Siemens soft starter 3RW30 and 3RW40 instruction manual

    Functional principle of Siemens soft starters 3RW30 and 3RW40 Siemens 3RW30 and 3RW40 soft starters have two anti-parallel thyristors in two of the three phases. In each phase, one thyristor for positive half-wave and one thyristor for negative half-wave are provided. The third is not The current in the controlled phase is the sum of the current in the controlled phase.
    Read more »
  7. Universal Circuit Breaker CW3 Series Instruction Manual

    Overview of CW3 Series Universal Circuit Breaker This type of circuit breaker is widely used and can be applied to AC400V and 690V.
    Read more »
  8. Siemens 3WT Circuit Breaker Manual

    Brief introduction of Siemens 3WT circuit breaker Generally speaking, the rated voltage of the equipment has two specifications, which are 500V and 690V respectively, and the current coverage of Siemens circuit breaker 3WT is between 400A and 4000 (3800)A. Its installation method can be divided into two types: fixed and withdrawable. Its breaking capacity can reach up to 66KA, which is generally suitable for 2500KVA capacity transformer system.
    Read more »
  9. Overview and troubleshooting of Siemens air circuit breaker 3WT

    Overview and troubleshooting of Siemens air circuit breaker 3WT Overview of Siemens Air Circuit Breaker 3WT ◆Environmental conditions Siemens circuit breakers are suitable for operation in enclosed spaces where the operating conditions are not affected by dust or corrosive steam/gas. In dusty or humid conditions, an appropriate enclosure must be used.
    Read more »
  10. Siemens air circuit breaker 3WT wiring diagram and glossary

    Overview of Siemens Air Circuit Breaker 3WT The 3WT series of Siemens circuit breakers have a total of 500V and 690V rated voltages, and its current coverage is between 400A and 4000 (3800)A. The circuit breaker can be installed in a fixed or withdrawable type, and its breaking capacity is up to 66KA, which is usually suitable for use in a 2500KVA capacity transformer system.
    Read more »