FOR THOSE WHO DON'T WANT TO TAKE THE 'LONG WAY', CHOOSE OKPLAZAS!

Monthly Archives: October 2020

  1. Omron Relay Model Collection

    Omron Relay Model Collection -Omron General Relay -For control cabinet -Slim I/O Relay (Model G2RV-SR): A low-profile and slim I/O relay with a global standard size and a width of 6.2mm. -Miniature power relay (model MY-GS): The general relay MY is equipped with mechanical indicator lights as standard, which can confirm the action status of the contacts.
    Read more »
  2. Schneider universal circuit breaker NS series installation and control circuit diagram

    Schneider universal circuit breaker NS series installation and control circuit diagram Schneider universal circuit breaker NS series (fixed) installation ◆Installation overview The fixed shape Schneider Compact NS series 630b-1600A specification universal circuit breaker can be installed vertically, horizontally or flat-mounted on the back. Its characteristics are not affected. The connection type is front-board connection.
    Read more »
  3. Schneider universal circuit breaker NS series model parameters and characteristic requirements

    Schneider universal circuit breaker NS series model parameters and characteristic requirements Brief overview of Schneider universal circuit breaker NS series The Compact NS series universal circuit breaker adopts a modular system design, which indirectly promotes the standardization of the power distribution cabinet, and the installation is quick and easy to make mistakes. All circuit breakers from NS630b to 1600A have only one external dimension, and they can be installed in parallel to reduce the use of space.
    Read more »
  4. Schneider universal circuit breaker Compact NS series control unit

    Schneider universal circuit breaker Compact NS series control unit Schneider universal circuit breaker "basic protection type" control unit Micrologic 2.0, 5.0 and 6.0 control units protect the power supply circuit. Micrologic 5.0 and 6.0 provide time selectivity during short circuit.
    Read more »
  5. Airtac standard cylinder SAIF series valve cylinder selection manual

    Airtac standard cylinder SAIF series valve cylinder selection manual Airtac standard cylinder SAI series overview ◆The structure diagram of various types of cylinders and accessories is shown below
    Read more »
  6. Airtac standard cylinder SAUF series valve cylinder model size description

    Airtac standard cylinder SAUF series valve cylinder model size description

    Overview of Airtac standard cylinder SAU and SAUF series

    ◆The composition diagram of the appearance structure is shown below.
    Read more »
  7. Siemens soft starter 3RW55 start function and principle

    Siemens soft starter 3RW55 start function and principle The start mode of the Siemens soft starter is used to determine the ramp mode of the motor after receiving the start command. The following starting modes can be set: ●Soft start based on voltage ramp Principle: Use a voltage ramp to achieve soft start. Within a definable ramp-up time, the 3RW55 soft starter will increase the motor voltage from the parameterized start voltage to the line voltage, which can be applied to conveyor belts or requires no severe interference when the drive starts In the system.
    Read more »
  8. Siemens soft starter 3RW55 installation, disassembly and wiring diagram

    Siemens soft starter 3RW55 installation, disassembly and wiring diagram Siemens soft starter 3RW55 installation ◆Install 3RW55 soft starter on the horizontal surface Claim: 1. Pay attention to the installation location, minimum clearance and environmental conditions mentioned in the data sheet.
    Read more »
  9. Siemens soft starter 3RW55 working principle and circuit diagram

    Siemens soft starter 3RW55 working principle and circuit diagram The working principle of Siemens soft starter 3RW55 The soft starter can be used to start a three-phase induction motor with a smaller torque and a lower starting current. After the start command is issued, the Siemens soft starter 3RW55 will immediately start the motor (t1). During the ramp-up period (t1 to t3), the current is conducted through the power semiconductor to make the motor start smoothly.
    Read more »
  10. Schneider Molded Case Circuit Breaker Powerpact Series Instruction Manual

    Schneider Molded Case Circuit Breaker Powerpact Series Instruction Manual Schneider Molded Case Circuit Breaker Powerpact Series Overview This series of Schneider molded case circuit breakers can be divided into two models, which are H-type and J-type. Their main function is to protect them from overload or short-circuit current when used in electrical systems. damage. When the pre-defined overcurrent level is reached, the molded case circuit breaker can automatically perform the circuit breaker action, and the overload and short circuit protection functions it can achieve are provided by the loaded thermal magnetic trip system.
    Read more »