Siemens air circuit breaker 3WL interlock function
The mechanical interlocking module can be used for 1 or 2 Siemens 3WL circuit breakers, and can be easily adjusted according to the corresponding model. Fixed and withdrawable circuit breakers are fully compatible, so they can be used in combination. This is also applicable to 3WT and 3WN1 circuit breakers.
Overview of Siemens Air Circuit Breaker 3WL
In order to protect Siemens circuit breakers and devices and prevent unauthorized operations by maintenance and operators, the device is equipped with a complete interlocking device and can be easily modified. More safety features include the following:
Overview of Siemens Leakage Circuit Breaker 5SM6AFD
Earlier leakage protection devices such as fuses, miniature circuit breakers and residual current operated protectors are not suitable for detecting arc faults, especially arc faults that are limited by impedance.
Siemens Molded Case Circuit Breaker 3VT8 Application
Various models of 3VT molded case circuit breakers are suitable for the following applications:
1. Used as input and output circuit breakers for power distribution system;
2. Used as switch and protection equipment for motors, transformers and capacitors;
3. Combined with a lockable rotary operating mechanism and terminal cover, it can be used as a main switch and an emergency stop switch.
Overview of Siemens miniature circuit breaker 5SL series
Based on the needs of customers, Siemens has launched a new generation of Siemens miniature circuit breaker 5SL series low-voltage terminal power distribution products for OEM customers. German quality, value model, let Siemens products always offer you escort.
Siemens circuit breaker overcurrent release
◆Overcurrent protection setting
Caution: Adjust the parameters only when the Siemens circuit breaker is off. If you modify the parameters when the circuit breaker is on, you may accidentally trip the circuit breaker.
Siemens circuit breaker 3WT installation method
Warning: Before installing the equipment, make sure that the minimum spacing requirements between insulating, grounding and conductive components are met in the switch cabinet.
Siemens circuit breaker 3WT debugging method
1. Store energy on the stored energy spring mechanism
Warning: It may cause personal injury. When the Siemens circuit breaker is removed from the system with the energy storage spring mechanism in a discharged state, it must be placed on a stable surface (for example, on a workbench used for maintenance).
Overview of ABB AC Contactor AX Series
First of all, the overall structure of the AX series contactor is relatively compact, and at the same time it is small in size, with long service life, high working stability, safety and reliability, and simple installation and maintenance.
1. The main parameters and significance of the electric energy meter
1. Voltage parameter: indicates the voltage of the applicable power supply. The single-phase voltage of our low-voltage working circuit is 220V, and the three-phase voltage is 380V.